Furnace Fault Codes
What your furnace's blinking light or error code actually means
Most furnaces report faults by flashing a status LED a set number of times, or by showing a code on a small display. Each entry below explains what a given signal means, what normally causes it, what you can safely check yourself, and when it needs a licensed technician.
First, check it is actually a fault
A blinking light is not automatically a problem — every brand uses the same light to say the furnace is running normally. The patterns that mean nothing is wrong lists every one of them.
Start with what the furnace is doing
If you have not got a code out of it yet, these describe the behaviour and list every code that produces it.
- Lights, then shuts off after a few seconds
- Igniter glows but the burners never light
- Nothing at all, no lights on the control board
- Runs for a while, then trips on high limit
- Inducer runs but the burners never come on
- Runs briefly, stops, starts again, then quits
Do not know the brand? Start with the count
The flashes mean different things on different furnaces, so the count on its own is not an answer — but these pages show every meaning side by side, which is usually enough to recognise the right one.
- Furnace flashing once
- Furnace flashing 2 times
- Furnace flashing 3 times
- Furnace flashing 4 times
- Furnace flashing 5 times
- Furnace flashing 6 times
- Furnace flashing 7 times
- Furnace flashing 8 times
- Furnace flashing 9 times
- Furnace flashing 10 times
- Furnace flashing 11 times
- Furnace flashing 12 times
Start with your manufacturer
- Goodman and Amana furnace fault codes — 80 codes (also Amana)
- Carrier, Bryant and Payne furnace status codes — 15 codes (also Bryant, Payne)
- Trane and American Standard furnace flash codes — 34 codes (also American Standard)
- Lennox furnace alert codes — 61 codes
- York, Luxaire and Coleman furnace flash codes — 25 codes (also Luxaire, Coleman)
- Rheem, Ruud and Weather King furnace blink codes — 10 codes (also Ruud, Weather King)
- Heil, Tempstar and Comfortmaker furnace codes — 15 codes (also Tempstar, Comfortmaker, Arcoaire, KeepRite)
- Armstrong Air, AirEase, Concord and Ducane furnace codes — 16 codes (also AirEase, Concord, Ducane)
By part
The same part produces several different codes, and several different brands word them differently. These pages collect every code that points at one component.
- Pressure switch — Furnace pressure switch codes on every brand
- High limit switch — Furnace high limit switch codes by brand
- Flame sensor — Furnace flame sensor codes on every brand
- Rollout switch — Furnace rollout switch codes: why it tripped
- Hot surface igniter — Furnace igniter fault codes by manufacturer
- Inducer / draft motor — Furnace inducer motor fault codes by brand
- Indoor blower motor — Furnace blower motor fault codes by brand
- Gas valve — Furnace gas valve fault codes by manufacturer
- Grounding and line polarity — Furnace grounding and reversed polarity codes
- Voltage and fuse — Furnace voltage and fuse codes by brand
Goodman and Amana
- 1 flash — Lockout after too many failed ignition attempts
- 2 flashes — Pressure switch is closed when it should be open
- 3 flashes — Pressure switch will not close
- 4 flashes — High limit switch is open — the furnace is overheating
- 5 flashes — Flame detected when no flame should be present
- 6 flashes — Rollout switch has tripped
- 7 flashes — Flame signal is too weak
- 8 flashes — Igniter circuit fault, most often caused by poor grounding
- 9 flashes — High stage pressure switch stuck open
- rapid flashing — Reversed 115 volt polarity, a grounding problem, or an open igniter circuit
- LED off — No power to the furnace, or an internal control fault
- continuous on — Normal operation — no fault stored
- 6 flashes — Rollout limit open, or control module fuse blown
Goodman and Amana display codes
- E0 — Lockout after too many failed ignition attempts
- E1 — Low stage pressure switch closed at the start of the heating cycle
- E2 — Low stage pressure switch stuck open
- E3 — High limit switch is open — the furnace is overheating
- E4 — Flame detected when no flame should be present
- E5 — Low voltage fuse is open
- E6 — Flame signal is too weak
- E7 — Igniter fault or improper grounding
- E8 — High stage pressure switch closed at the start of the heating cycle
- E9 — High stage pressure switch stuck open
- EA — Reversed 115 volt polarity
- Ed — Rollout switch has tripped
- EC — Inducer motor overcurrent
- EF — Auxiliary switch or input is open
Goodman and Amana blower codes
- b0 — Blower motor is not running
- b1 — Blower communication error
- b2 — Blower motor horsepower mismatch
- b3 — Blower motor operating at a power, temperature, or speed limit
- b4 — Blower motor current trip or lost rotor
- b5 — Blower motor locked rotor
- b6 — Blower motor over or under voltage trip, or over temperature trip
- b7 — Incomplete parameters sent to the motor
- b9 — Low indoor airflow
- d0 — Data not yet on network
- d4 — Invalid memory card data
Carrier and Bryant
- Status code 11 — No previous code stored
- Status code 12 — Blower running after power up
- Status code 13 — Limit circuit lockout
- Status code 14 — Ignition lockout
- Status code 21 — Gas heating lockout — will not reset automatically
- Status code 22 — Abnormal flame-proving signal — flame detected with the gas valve closed
- Status code 23 — Pressure switch did not open
- Status code 24 — Secondary voltage fuse is open
- Status code 31 — Pressure switch did not close, or reopened
- Status code 33 — Limit circuit fault — a limit or flame rollout switch is open
- Status code 34 — Ignition proving failure
- Status code 45 — Control circuitry lockout
- LED continuously off — No power reaching the control
- LED rapid flashing — Line voltage polarity reversed
- Status code retrieval, amber LED controls — How to read stored status codes on Carrier amber LED boards
Trane and American Standard
- 2 flashes — System lockout — retries or recycles exceeded
- 3 flashes — Draft pressure error
- 4 flashes — Open high limit device
- 5 flashes — Flame sensed when no flame should be present
- 6 flashes — 115 volt AC power reversed, or poor grounding
- 7 flashes — Gas valve circuit error
- 8 flashes — Low flame sense signal
- 9 flashes — Ignitor circuit problem, or low voltage between neutral and 24 volt common
- Flashing slow — Normal — no call for heat
- Flashing fast — Normal — call for heat
- Continuous on — Replace the integrated furnace control
- Continuous off — Check power
Rheem, Ruud and Weather King
- 1 blink — Soft lockout, one hour
- 2 blinks — Pressure switch failure — switch remains open
- 3 blinks — Limit switch open
- 4 blinks — Pressure switch failure — switch remains closed
- 5 blinks — Twinning circuit failure
Goodman GMEC96 and Amana AMEC96 colour codes
- 1 red flash — Flame sensed when no flame should be present
- 2 red flashes — Pressure switch stuck closed, or an inducer error
- 3 red flashes — First stage pressure switch stuck open, or an inducer error
- 3 double red flashes — Second stage pressure switch stuck open, or an inducer error
- 4 red flashes — Open limit switch
- 5 red flashes — Open rollout switch, or open fuse detected
- 6 red flashes — Pressure switch cycle lockout
- 7 red flashes — External lockout — ignition retries exhausted
- 8 red flashes — External lockout — recycles exhausted
- 9 red flashes — Grounding problem or reversed polarity
- 10 red flashes — Gas flow detected with a call for heat
- 11 red flashes — Limit switch open due to blower failure
- 12 red flashes — Ignitor relay failure
- rapid amber flashing — Low flame sense current
- rapid red flashing — Twinning error
- solid red — Internal control fault, gas valve error, microprocessor or frequency check failure
- 3 amber flashes — Second stage heat called with no first stage call
- 4 amber flashes — Cooling called with no fan call
- 1 amber flash — Normal operation — first stage heat
- solid green — Standby — powered, no call
- 2 amber flashes — Normal operation — second stage heat
- 1 green flash — Normal operation — low stage cooling
- 2 green flashes — Normal operation — high stage or single stage cooling
- rapid green flashing — Normal operation — fan only, no heating or cooling
Lennox communicating alert codes
- Alert code 200 — Rollout limit switch open
- Alert code 204 — Check gas valve
- Alert code 205 — Gas valve relay contact closed
- Alert code 206 — Gas valve second stage relay fault
- Alert code 207 — Hot surface igniter sensed open
- Alert code 223 — Low pressure switch open
- Alert code 226 — High pressure switch stuck closed
- Alert code 227 — Low pressure switch open in run mode
- Alert code 228 — Inducer calibration issue
- Alert code 229 — Ignition on high fire — information only
- Alert code 240 — Low flame current in run mode
- Alert code 241 — Flame out of sequence — still present
- Alert code 250 — Primary limit switch open
- Alert code 252 — Discharge air temperature high
- Alert code 270 — Flame failed to ignite — Watchguard
- Alert code 271 — Low pressure switch open — Watchguard
- Alert code 272 — Low pressure switch open in run mode — Watchguard
- Alert code 273 — Flame failed in run mode — Watchguard
- Alert code 274 — Primary limit switch open more than three minutes — Watchguard
- Alert code 201 — Indoor blower motor communication lost
- Alert code 202 — Blower motor and unit size mismatch
- Alert code 203 — Invalid or unset unit size code
- Alert code 275 — Flame out of sequence — Watchguard
- Alert code 276 — Furnace calibration failure, or high pressure switch fault
- Alert code 290 — Ignition circuit fault — Watchguard
- Alert code 291 — Heating airflow below minimum — Watchguard
- Alert code 292 — Indoor blower motor will not start — Watchguard
- Alert code 294 — Inducer motor overcurrent — Watchguard
- Alert code 370 — Interlock switch open — no 24 volts at the DS terminal
- Alert code 116 — High 24 volt secondary voltage
- Alert code 117 — Poor earth ground on the reporting unit
- Alert code 224 — Low pressure switch stuck closed
- Alert code 225 — High pressure switch will not close
- Alert code 295 — Indoor blower motor overheating
- Alert code 344 — Y1 relay stuck on the furnace control
- Alert code 349 — O to R jumper cut on the furnace control
York, Luxaire and Coleman
- Fault code retrieval — How to read and clear stored fault codes on York UTEC boards
- Green heartbeat — Normal operation, no call for heat, no active errors
- Amber heartbeat — Normal operation with a call for heat
- 1 red flash — Flame sensed with the gas valve off
- 3 red flashes — Pressure switch open, or first stage pressure switch open
- 3 double red flashes — Second stage pressure switch stuck open
- 5 red flashes — Open rollout switch
- 6 red flashes — Pressure switch cycle lockout
- 7 red flashes — One hour lockout after ignition retries
- 8 red flashes — Lockout on recycles, flame dropouts
- 9 red flashes — Grounding, reversed polarity, or reversed transformer leads
- 10 red flashes — Gas valve energised with no call for heat
- 11 red flashes — Limit switch open more than five minutes — blower failure
- 12 red flashes — Open hot surface igniter
- Rapid red flashing — Twinning error or incorrect 24 volt phasing
- Rapid amber flashing — Low flame sense current
- Solid LED — Control fault detected
- Steady off — No power to the board, or control failure
- 2 red flashes — Pressure switch stuck closed, or an inducer error
- 4 red flashes — Open high limit switch
- 3 amber flashes — Second stage heat present with no first stage call
- 4 amber flashes — Cooling called with no fan call
- 2 amber flashes — Normal operation with a call for second stage heat
- Which York control board you have — York used two control board generations with different code meanings
- 1 amber flash — Normal operation with a call for heat, Emerson boards
Reading the codes
- Reading a furnace fault code — How to find, count, and interpret the diagnostic light before looking anything up
- When to stop and call someone — The furnace conditions that are not a diagnosis problem
- The same code means different things — Four of the six biggest furnace brands publish more than one code list
Goodman modulating display codes
- IF — Internal control fault
- Ft — Field test mode
- On — Normal operation
- F — Continuous fan
- A — Airflow display, followed by the CFM value
- H — Gas heat demand, followed by the demand percentage
- HI — High heat at 100 per cent demand
- LO — Low stage heat
- dF — Defrost demand
- P1 — Low stage compressor, heating mode
- P2 — High stage compressor, heating mode
- C1 — Low stage compressor, cooling mode
- C2 — High stage compressor, cooling mode
- C — Compressor cooling with a single stage compressor
- P — Compressor heating with a single stage compressor
- d — Dehumidification cooling with a single stage compressor
- d1 — Dehumidification, low stage cooling, communicating mode
- d2 — Dehumidification, high stage cooling, communicating mode
Heil, Tempstar and Comfortmaker
- Which diagnostic system you have — Heil, Tempstar and Comfortmaker furnaces use two different code systems that contradict each other
- Heartbeat — Normal operation — standby or a call for heat
- LED off — The control is not powered
- 1 flash — Not used — if you are counting one flash, count again
- 2 flashes — Low pressure switch closed when it should be open
- 3 flashes — Low pressure switch still open 30 seconds after the inducer started
- 4 flashes — Limit switch string is open
- 5 flashes — Flame sensed out of sequence — flame signal still present
- 6 + 1 flashes — Soft lockout — failed to light within four trials for ignition
- 6 + 2 flashes — Soft lockout — flame lost during run, cycling pressure switch, or blocked condensate
- 6 + 3 flashes — Soft lockout — airflow proving circuit opened during the run
- 6 + 4 flashes — Soft lockout — limit circuit opened during the run
- 7 flashes — Soft lockout — limit trips taking longer than two minutes to reset
- 8 flashes — High pressure switch closed when it should be open
- 9 flashes — High pressure switch open when it should be closed
Armstrong Air, AirEase, Concord and Ducane
- Heartbeat — Control powered, no errors detected
- Error code recall — The last ten faults, retained even through a power cut
- LED off — No power to the control, or a control hardware fault
- 1 flash — Reverse line voltage polarity
- 2 flashes — Improper earth ground
- 3 flashes — Burner failed to light, or lost flame during a heat demand
- 4 flashes — Low flame signal — check the flame sensor
- 5 flashes — Watchguard — burner failed to light, retries or recycles exceeded
- 7 flashes — Primary or secondary limit open, or Watchguard after three minutes open
- 8 flashes — Rollout switch open
- 9 flashes — Pressure switch failed to close, or opened during a heat demand
- 10 flashes — Watchguard — pressure switch opened five times during one heat demand
- 11 flashes — Pressure switch stuck closed before the inducer started
- 12 flashes — Flame sensed without the gas valve energised
- 13 flashes — Low line voltage
- 6 flashes — Not used — if you are counting six flashes, count again
Rheem condensing furnace blink codes
- Which blink code list applies — Rheem publishes two blink code lists that contradict each other
- 1 blink — Limit circuit is open
- 2 blinks — Pressure switch did not close within 10 seconds
- 3 blinks — Pressure switch closed when it should be open
- 4 blinks — Lockout after five failed ignition attempts
Lennox seven-segment diagnostic codes
- Which Lennox code list applies — Lennox uses two code systems, and knowing which you are reading matters
- E200 — Hard lockout — rollout circuit open
- E204 — Gas valve mis-wired
- E223 — Pressure switch failed open
- E224 — Pressure switch failed closed
- E227 — Pressure switch opened during ignition or run
- E240 — Low flame current in run mode
- E241 — Flame sensed out of sequence — flame still present
- E250 — Limit switch circuit open
- E290 — Ignitor circuit fault — failed ignitor or triggering circuit
- E270 — Soft lockout — retries exceeded, no flame current sensed
- E271 — Soft lockout — retries exceeded, pressure switch opened
- E272 — Soft lockout — recycles exceeded, pressure switch opened
- E273 — Soft lockout — recycles exceeded after flame failure
- E274 — Soft lockout — recycles exceeded, limit circuit opened
- E275 — Soft lockout — flame sensed out of sequence, signal now gone
- E110 — Low line voltage
- E111 — Line voltage polarity reversed
- E112 — Ground not detected — system shuts down
- E113 — High line voltage
- E114 — Line voltage frequency out of range
- E115 — Low 24 volt supply
- E117 — Poor ground detected — warning only
- E106 — Twin communication fault
- E163 — Furnace control board failure
Trane and American Standard seven-segment codes
- Which Trane code system you have — Trane furnaces use either flash codes or a seven-segment display, and they share no numbering
- E2.1 — Retry exceeded — flame never sensed, one hour lockout
- E2.2 — Recycles exceeded — flame sensed then lost, one hour lockout
- E3.2 — Open pressure switch, first stage
- E3.4 — Open pressure switch, second stage
- E04 — Open limit — thermal, rollout, or reverse airflow switch
- E05 — Flame detected when it should not be present
- E6.1 — Line voltage polarity reversed
- E6.2 — Bad grounding
- E6.3 — Igniter relay failed, or igniter open
- E08 — Flame current low but still usable
- E09 — Open inducer limit switch or condensate pressure switch
- E01 — Internal control failure
- E2.3 — First stage gas valve not energised when it should be, ten times
- E3.1 — Shorted pressure switch, first stage
- E3.3 — Shorted pressure switch, second stage
- E7.1 — First stage gas valve energised when it should be off
- E11 — Gas valve relay faults — five conditions in one code
- E12 — Open fuse
- E17 — Blower motor not responding to communication
- E18 — Blower communication failure on the control
- IdL, Xt1, Xt2, aRF and the other status codes — Normal operation — the display is not showing a fault