Lennox furnace Alert code 275: Flame out of sequence — Watchguard
Alert 275 means the furnace detected flame when there should be none, and has gone into Watchguard mode. Lennox's first instruction for it is to shut off the gas.
Applies to: Lennox communicating gas furnaces on systems using the S30, S40 or comparable communicating thermostats, as documented in the Lennox Residential Communicating Systems Alert Code Guide.
What it means
The control watches the flame sensor at times when the gas valve is closed and no flame should exist. If it reads a flame signal in that window, something is wrong in a way the furnace cannot safely work around, so it shuts down into Watchguard rather than continuing. The reason this matters more than most alerts is what it implies: either the gas valve is passing gas when it is commanded shut, or the flame sensing circuit is reporting a flame that is not there. The first is a gas leak into a hot chamber. Lennox does not treat this as a diagnostic exercise — the published instruction is to shut off the gas, check for a gas valve leak, and replace the valve if needed. Alert 250 reports the same underlying condition without the Watchguard lockout.
Most common causes
- A gas valve leaking through when it is commanded closed, which is the possibility that dictates the response.
- A short in the flame sensing circuit reporting a flame that is not present.
- A burner still glowing hot enough after shutdown to produce a flame signal.
- Damaged or shorted flame sensor wiring.
- A failed control board misreading the sense input.
How to diagnose it
- Do not treat this as something to investigate before acting. Lennox's own first step is to shut off the gas.
- Note the alert number before clearing it, since 275 and 250 describe the same condition at different severities.
- Note whether there is any smell of gas. If there is, leave the building and call the gas utility from outside.
- Leave everything beyond that to a licensed technician.
How to fix it
- Shut off the gas supply to the furnace at the manual valve.
- Call a licensed technician. This is not a homeowner repair under any circumstances.
- Expect the technician to check the gas valve for leak-through and to check for voltage reaching the valve when it should be de-energised.
- Expect the gas valve to be replaced if it is passing gas.
Notes
Watchguard is Lennox's term for a soft lockout the control clears itself, in this case on a successful ignition. That self-clearing is what makes the alert dangerous to ignore: the furnace may appear to recover and run normally while the underlying valve fault is unchanged.