Heil furnace 6 + 1 flashes: Soft lockout — failed to light within four trials for ignition

Six flashes then one is a combination code. Six means soft lockout; the one that follows says why — the maximum retry count was exceeded after four failed attempts to light.

Applies to: International Comfort Products *9MPT and *9MPV gas furnaces using the Honeywell SV9541Q SmartValve, sold as Heil, Tempstar and Comfortmaker.

What it means

This control uses a two-part pattern for lockouts, and understanding it makes several codes readable at once. Six flashes means the control is in soft lockout. The count that follows says what put it there. Six-then-one is the maximum retry count exceeded: the furnace tried four times to establish a flame and never proved one. ICP documents that after a five minute delay the SmartValve attempts a new ignition sequence if the call for heat is still present, and that resetting the thermostat initiates a new sequence immediately. So a furnace on this code produces a burst of attempts, waits five minutes, and tries again — not intermittent operation, but a documented retry cycle.

Most common causes

How to diagnose it

  1. Count the pattern properly: six flashes, a pause, then one. Reading it as seven gives a completely different fault.
  2. Check the gas valve's own on/off switch, which is a documented cause of ignition problems on this control.
  3. Check whether other gas appliances work. If none do, the problem is the gas supply.
  4. Watch a start attempt. Whether the burners light at all is the key split — lighting then going out points at flame sensing, never lighting points at gas or the igniter.
  5. Note the five-minute retry rhythm, which confirms the documented behaviour.

How to fix it

  1. Restore the gas supply if that is the cause, and check the manual valve is open.
  2. Igniter replacement, flame sensor cleaning and gas pressure testing are technician work.
  3. Do not reset repeatedly to force a run. Each reset delivers gas to a burner that may not light it.
  4. Tell the technician whether the burners light at all. That single observation splits the diagnosis in half.

Notes

Combination codes are easy to misread as a single longer count. Watching two or three full cycles before deciding is worth the extra half minute, especially here where seven flashes is a different fault entirely.

Related

All codes for this manufacturer

Heil, Tempstar and Comfortmaker furnace codes — every code, with what differs between models.

This code is not a homeowner repair. Faults in this group involve the gas valve, the burner compartment, or the heat exchanger — the parts whose failure can put combustion products, including carbon monoxide, into the air the house breathes. Do not reset it repeatedly to keep the heat on. Have it looked at by a licensed technician, and make sure there is a working carbon monoxide alarm on every level of the home, including the level the furnace is on.

Sources

This site is a reference, not a substitute for a licensed HVAC technician. Gas appliances can leak carbon monoxide and cause fire. Anything involving gas lines, the heat exchanger, or the flame sensing circuit should be handled by a licensed professional. Pages are written with AI assistance from the sources listed on each page and checked against them before publishing.