Goodman furnace 9 flashes: High stage pressure switch stuck open

Nine flashes means the second-stage pressure switch did not close when the furnace tried to run on high fire. Low-stage heating usually still works, so the symptom is a furnace that heats but never gets to full output.

Applies to: Goodman GMV8 and GMV9 and Amana AMV9 two-stage gas furnaces with a single red diagnostic LED. Single-stage models have no high stage switch and do not produce this code.

What it means

A two-stage furnace has two pressure switches, one for each firing rate, because high fire moves more combustion air and needs its own proof of draft. This code means the high-stage switch failed to close when the control called for second-stage heat. The practical consequence is distinctive: the furnace is not dead. It runs on low fire, which on a mild day may be entirely adequate, so the fault often goes unnoticed until the weather turns and the house cannot keep up. A furnace that used to satisfy the thermostat and now runs constantly without reaching setpoint is the usual way people meet this code.

Most common causes

How to diagnose it

  1. Confirm the furnace is actually two-stage. A single-stage model producing nine flashes means you have miscounted.
  2. Note whether the house heats slowly rather than not at all. That pattern fits this fault and rules out several others.
  3. Check the vent termination outside, as with any pressure switch fault. A partial restriction is exactly what produces a high-stage-only failure.
  4. Check the condensate drain for slow drainage rather than complete blockage.
  5. Note whether the fault appeared after a service visit, since swapped switches are a real and easily missed cause.

How to fix it

  1. Clear the vent termination and the condensate drain if either is restricted. Both are within homeowner reach and both cause this.
  2. The pressure switches, hoses, and inducer are technician work, for the same reason as every other pressure switch fault — they prove safe venting.
  3. Have the technician confirm the two switches are fitted the right way round if the furnace was recently serviced.
  4. Do not run the furnace indefinitely on low fire and ignore the code. The partial restriction that causes it usually gets worse, and at some point it will affect low fire too.

Notes

A furnace stuck on low fire is easy to live with in mild weather and impossible to live with in a cold snap. This code is worth acting on when it appears rather than when the house stops keeping up, because the two are typically several weeks and one weather change apart.

Related

All codes for this manufacturer

Goodman and Amana furnace fault codes — every code, with what differs between models.

Not sure this is your brand?

The same count means something else on other furnaces. What 9 flashes means on every brand puts them side by side.

Sources

This site is a reference, not a substitute for a licensed HVAC technician. Gas appliances can leak carbon monoxide and cause fire. Anything involving gas lines, the heat exchanger, or the flame sensing circuit should be handled by a licensed professional. Pages are written with AI assistance from the sources listed on each page and checked against them before publishing.