Furnace pressure switch codes on every brand
More fault codes point at the pressure switch than at any other part of a furnace. Here is what each manufacturer's pressure switch codes mean, and why the same switch produces two opposite faults.
What the pressure switch does
The pressure switch is a safety interlock that proves the inducer is actually moving air before the control will open the gas valve. It is a simple diaphragm switch connected by a small hose to the inducer housing or the vent. Suction from a running inducer pulls the diaphragm over and closes the contacts; with no suction the contacts sit open.
Why one part produces several different codes
That is why every manufacturer reports two different pressure switch faults rather than one. Stuck open means the inducer is running but the switch never closed — usually a blocked vent or intake, a cracked or disconnected hose, water in the hose or the collector box, or a failed inducer. Stuck closed means the switch was already closed before the inducer started, which the control reads as a switch that cannot prove anything and therefore cannot be trusted. The first is far more common in cold weather; the second normally means a failed switch or a shorted circuit.
Every pressure switch code on this site
35 codes across 10 control families. The meaning is the manufacturer's, from the document listed at the foot of each code page.
| Brand | Code | What it reports |
|---|---|---|
| Armstrong | 10 flashes | Watchguard — pressure switch opened five times during one heat demand |
| Armstrong | 11 flashes | Pressure switch stuck closed before the inducer started |
| Armstrong | 9 flashes | Pressure switch failed to close, or opened during a heat demand |
| Carrier | Status code 23 | Pressure switch did not open |
| Carrier | Status code 31 | Pressure switch did not close, or reopened |
| Goodman | 2 flashes | Pressure switch is closed when it should be open |
| Goodman | 3 flashes | Pressure switch will not close |
| Goodman | 9 flashes | High stage pressure switch stuck open |
| Goodman | E1 | Low stage pressure switch closed at the start of the heating cycle |
| Goodman | E2 | Low stage pressure switch stuck open |
| Goodman | E8 | High stage pressure switch closed at the start of the heating cycle |
| Goodman | E9 | High stage pressure switch stuck open |
| Goodman | 2 red flashes | Pressure switch stuck closed, or an inducer error |
| Goodman | 3 double red flashes | Second stage pressure switch stuck open, or an inducer error |
| Goodman | 3 red flashes | First stage pressure switch stuck open, or an inducer error |
| Goodman | 6 red flashes | Pressure switch cycle lockout |
| Heil | 2 flashes | Low pressure switch closed when it should be open |
| Heil | 3 flashes | Low pressure switch still open 30 seconds after the inducer started |
| Heil | 6 + 2 flashes | Soft lockout — flame lost during run, cycling pressure switch, or blocked condensate |
| Heil | 8 flashes | High pressure switch closed when it should be open |
| Heil | 9 flashes | High pressure switch open when it should be closed |
| Lennox | Alert code 223 | Low pressure switch open |
| Lennox | Alert code 226 | High pressure switch stuck closed |
| Lennox | Alert code 227 | Low pressure switch open in run mode |
| Lennox | Alert code 271 | Low pressure switch open — Watchguard |
| Lennox | Alert code 272 | Low pressure switch open in run mode — Watchguard |
| Lennox | Alert code 276 | Furnace calibration failure, or high pressure switch fault |
| Rheem | 2 blinks | Pressure switch did not close within 10 seconds |
| Rheem | 3 blinks | Pressure switch closed when it should be open |
| Rheem | 2 blinks | Pressure switch failure — switch remains open |
| Rheem | 4 blinks | Pressure switch failure — switch remains closed |
| York | 2 red flashes | Pressure switch stuck closed, or an inducer error |
| York | 3 double red flashes | Second stage pressure switch stuck open |
| York | 3 red flashes | Pressure switch open, or first stage pressure switch open |
| York | 6 red flashes | Pressure switch cycle lockout |
Before you work on it
A pressure switch that will not close is often the furnace correctly refusing to fire because the flue is blocked. Bypassing or jumpering it defeats the interlock that prevents combustion products entering the house.
Other parts
- Furnace high limit switch codes by brand
- Furnace flame sensor codes on every brand
- Furnace rollout switch codes: why it tripped
- Furnace igniter fault codes by manufacturer
- Furnace inducer motor fault codes by brand
- Furnace gas valve fault codes by manufacturer
- Furnace grounding and reversed polarity codes
Sources
Every code meaning above comes from the manufacturer document behind its code page:
- Allied Air Enterprises — A80UH1E and 80G1UHE Installation Instructions 507330-03, Table 7: Diagnostic Codes for -02 Control
- Carrier 58MCB Service Manual, 327884-101 Rev. B — status codes
- Goodman Manufacturing — Diagnostic Code Identification System (model-specific fault code lookup)
- International Comfort Products *9MPT and *9MPV installation instructions — Gas Valve Diagnostic Codes (third-party archive of the ICP document)
- Lennox Residential Communicating Systems Alert Code Guide, document 100017, March 2023 — Table 2, Alert Codes and Troubleshooting
- Rheem Gas Furnaces Installation Instructions 708503a — *RC 92+ Full Size Upflow and *RL 90+ Full Size Downflow Condensing Furnaces, Sequence of Operation
- Rheem Professional Technical Support — Standard Gas Furnace Diagnostic Flash Codes
- Johnson Controls Unitary Products technical service letter ST-045-09 — York UTEC furnace boards, fault code tables and retrieval procedure