Furnace Fault Codes

Rheem furnace 1 blink: Limit circuit is open

On these condensing furnaces a steady single blink means the limit circuit is open. The furnace runs the inducer and the circulating blower to clear the heat and refuses to do anything else until the limit closes.

Applies to: Rheem, Ruud and Weather King *RC 92+ full size upflow and *RL 90+ full size downflow condensing furnaces, per installation instructions 708503a. On Rheem's standard gas furnaces one blink means something else entirely — see the note below.

What it means

The control checks the limit circuit and, when it finds it open, energises the inducer and the conditioned air blower deliberately — that is the furnace moving air to bring the temperature down, not the furnace trying to run. Rheem's wording is that all other system functions are inoperable until the limit circuit closes, and that while the limit is open the red LED pulses at one blink per unit time. So this is not a stored fault code that survives the event; it is a live indication that reflects the state of the circuit right now, and it stops as soon as the limit closes. An open limit means the furnace exceeded its design temperature, and on a condensing furnace that almost always means airflow.

Most common causes

How to diagnose it

  1. Check the air filter first. It is the most common cause and it is homeowner work.
  2. Confirm the supply registers and return grilles around the house are open and unobstructed.
  3. Note whether the blower is running while the burners are not — on this control that is the expected behaviour for this code, not a separate fault.
  4. Confirm the model number begins RC or RL before using this page. On a standard Rheem furnace one blink means a one-hour soft lockout instead.

How to fix it

  1. Replace a dirty filter and clear any blocked registers, then see whether the indication clears.
  2. If it returns with a clean filter and open registers, the restriction is in the ductwork or the blower, and that is technician work.
  3. A limit switch that is open with no overheat present is a failed switch, but that is a measurement rather than an assumption.
  4. Do not bypass the limit. It is the protection against the heat exchanger overheating.

Notes

The most important thing on this page is the model check. Rheem's standard flash code list assigns one blink to a one-hour soft lockout, which would send a reader looking for an ignition problem instead of an airflow problem.

Related

All codes for this manufacturer

Rheem, Ruud and Weather King furnace blink codes — every code, with what differs between models.

Not sure this is your brand?

The same count means something else on other furnaces. What 1 flash means on every brand puts them side by side.

This code is not a homeowner repair. Faults in this group involve the gas valve, the burner compartment, or the heat exchanger — the parts whose failure can put combustion products, including carbon monoxide, into the air the house breathes. Do not reset it repeatedly to keep the heat on. Have it looked at by a licensed technician, and make sure there is a working carbon monoxide alarm on every level of the home, including the level the furnace is on.

Sources

This site is a reference, not a substitute for a licensed HVAC technician. Gas appliances can leak carbon monoxide and cause fire. Anything involving gas lines, the heat exchanger, or the flame sensing circuit should be handled by a licensed professional. Pages are written with AI assistance from the sources listed on each page and checked against them before publishing.