Goodman and Amana furnace fault codes
Goodman and Amana furnaces share control boards and share fault codes. What a given code means depends on which board your furnace has — and the same flash count means different things across the range.
Also covers: Amana — same manufacturer, same controls, same codes.
Goodman and Amana are the same manufacturer and use the same integrated furnace controls, so a code list for one applies to the other. Three different diagnostic systems appear across the range, and knowing which one you are looking at is the first step: older single-LED boards flash a count, later boards show a two-character alphanumeric code on a small display, and the GMEC96 and AMEC96 use a three-colour LED where the colour carries as much meaning as the count. The model number on the rating plate tells you which.
Worth knowing before you count
Six flashes means a rollout switch on a GMS or GMH board, but on a GMSS9 or AMSS9 it covers a rollout limit or a blown control fuse — a serious combustion fault and a minor electrical one, sharing a count. And on the GMEC96 three-colour boards, one red flash and one amber flash mean completely different things.
Goodman and Amana
- 1 flash — Lockout after too many failed ignition attempts
- 2 flashes — Pressure switch is closed when it should be open
- 3 flashes — Pressure switch will not close
- 4 flashes — High limit switch is open — the furnace is overheating
- 5 flashes — Flame detected when no flame should be present
- 6 flashes — Rollout switch has tripped
- 7 flashes — Flame signal is too weak
- 8 flashes — Igniter circuit fault, most often caused by poor grounding
- 9 flashes — High stage pressure switch stuck open
- rapid flashing — Reversed 115 volt polarity, a grounding problem, or an open igniter circuit
- LED off — No power to the furnace, or an internal control fault
- continuous on — Normal operation — no fault stored
- 6 flashes — Rollout limit open, or control module fuse blown
Goodman and Amana display codes
- E0 — Lockout after too many failed ignition attempts
- E1 — Low stage pressure switch closed at the start of the heating cycle
- E2 — Low stage pressure switch stuck open
- E3 — High limit switch is open — the furnace is overheating
- E4 — Flame detected when no flame should be present
- E5 — Low voltage fuse is open
- E6 — Flame signal is too weak
- E7 — Igniter fault or improper grounding
- E8 — High stage pressure switch closed at the start of the heating cycle
- E9 — High stage pressure switch stuck open
- EA — Reversed 115 volt polarity
- Ed — Rollout switch has tripped
- EC — Inducer motor overcurrent
- EF — Auxiliary switch or input is open
Goodman and Amana blower codes
- b0 — Blower motor is not running
- b1 — Blower communication error
- b2 — Blower motor horsepower mismatch
- b3 — Blower motor operating at a power, temperature, or speed limit
- b4 — Blower motor current trip or lost rotor
- b5 — Blower motor locked rotor
- b6 — Blower motor over or under voltage trip, or over temperature trip
- b7 — Incomplete parameters sent to the motor
- b9 — Low indoor airflow
- d0 — Data not yet on network
- d4 — Invalid memory card data
Goodman GMEC96 and Amana AMEC96 colour codes
- 1 red flash — Flame sensed when no flame should be present
- 2 red flashes — Pressure switch stuck closed, or an inducer error
- 3 red flashes — First stage pressure switch stuck open, or an inducer error
- 3 double red flashes — Second stage pressure switch stuck open, or an inducer error
- 4 red flashes — Open limit switch
- 5 red flashes — Open rollout switch, or open fuse detected
- 6 red flashes — Pressure switch cycle lockout
- 7 red flashes — External lockout — ignition retries exhausted
- 8 red flashes — External lockout — recycles exhausted
- 9 red flashes — Grounding problem or reversed polarity
- 10 red flashes — Gas flow detected with a call for heat
- 11 red flashes — Limit switch open due to blower failure
- 12 red flashes — Ignitor relay failure
- rapid amber flashing — Low flame sense current
- rapid red flashing — Twinning error
- solid red — Internal control fault, gas valve error, microprocessor or frequency check failure
- 3 amber flashes — Second stage heat called with no first stage call
- 4 amber flashes — Cooling called with no fan call
- 1 amber flash — Normal operation — first stage heat
- solid green — Standby — powered, no call
Goodman modulating display codes
- IF — Internal control fault
- Ft — Field test mode
- On — Normal operation
- F — Continuous fan
- A — Airflow display, followed by the CFM value
- H — Gas heat demand, followed by the demand percentage
- HI — High heat at 100 per cent demand
- LO — Low stage heat
- dF — Defrost demand
- P1 — Low stage compressor, heating mode
- P2 — High stage compressor, heating mode
- C1 — Low stage compressor, cooling mode
- C2 — High stage compressor, cooling mode
Other manufacturers
- Carrier, Bryant and Payne furnace status codes
- Trane and American Standard furnace flash codes
- Lennox furnace alert codes
- York, Luxaire and Coleman furnace flash codes
- Rheem, Ruud and Weather King furnace blink codes
- Heil, Tempstar and Comfortmaker furnace codes
- Armstrong Air, AirEase, Concord and Ducane furnace codes