Furnace Fault Codes

Furnace inducer runs but burners never light

The small blower at the top of the furnace spins up and keeps running, but the igniter never glows and the burners never light. The furnace is waiting for a signal that never comes.

What is actually happening

The inducer starts first in every heating sequence. Before the control will go any further, it has to see the pressure switch close — a diaphragm switch connected by a small hose to the inducer housing, which closes when the inducer generates enough suction. That switch is what proves the flue is clear and the inducer is actually moving air. Until it closes, the control will not energise the igniter, and it will certainly not open the gas valve.

What causes it

In cold weather the most common cause is a blocked intake or exhaust termination outside — snow, ice, a bird's nest, or a plastic cap left on. Then: water in the pressure switch hose or in the condensate trap, a cracked, kinked or disconnected hose, a blocked condensate drain backing water into the collector box, a failing inducer that spins but does not develop enough suction, or a failed switch. An inducer that hums, spins slowly, or has a bearing noise will look alive and still not close the switch.

The codes that report this

18 codes across 9 control families. Each links to what that manufacturer says about it.

BrandCodeWhat it reports
Armstrong10 flashesWatchguard — pressure switch opened five times during one heat demand
Armstrong9 flashesPressure switch failed to close, or opened during a heat demand
CarrierStatus code 31Pressure switch did not close, or reopened
Goodman3 flashesPressure switch will not close
Goodman9 flashesHigh stage pressure switch stuck open
GoodmanE2Low stage pressure switch stuck open
GoodmanE9High stage pressure switch stuck open
Goodman3 double red flashesSecond stage pressure switch stuck open, or an inducer error
Goodman3 red flashesFirst stage pressure switch stuck open, or an inducer error
Heil3 flashesLow pressure switch still open 30 seconds after the inducer started
Heil9 flashesHigh pressure switch open when it should be closed
LennoxAlert code 223Low pressure switch open
LennoxAlert code 227Low pressure switch open in run mode
LennoxAlert code 271Low pressure switch open — Watchguard
LennoxAlert code 272Low pressure switch open in run mode — Watchguard
Rheem2 blinksPressure switch did not close within 10 seconds
York3 double red flashesSecond stage pressure switch stuck open
York3 red flashesPressure switch open, or first stage pressure switch open

Worth knowing

This is the furnace correctly refusing to burn gas because it cannot prove the flue is clear. Jumpering the pressure switch to force it to run defeats the interlock that stops combustion products entering the house.

Other symptoms

This site is a reference, not a substitute for a licensed HVAC technician. Gas appliances can leak carbon monoxide and cause fire. Anything involving gas lines, the heat exchanger, or the flame sensing circuit should be handled by a licensed professional. Pages are written with AI assistance from the sources listed on each page and checked against them before publishing.