Goodman furnace d: Dehumidification cooling with a single stage compressor
A lower case d means the system is cooling for humidity control rather than for temperature. The blower is deliberately running slower than normal.
Applies to: Goodman GMVM97, GCVM97 and Amana AMVM97 modulating gas furnaces with a two-character display, set up with a single stage compressor and a humidity-controlling thermostat.
What it means
Dehumidification mode is a real operating mode, not a fault, and it looks wrong to anyone who does not know it exists. When a humidity-controlling thermostat calls for moisture removal, the control slows the indoor blower. Slower air spends longer over the cold evaporator coil, gets colder, and condenses more water out of it — better moisture removal at the cost of less airflow. So the symptom is a system that seems to be running weakly on a humid day, which is exactly what it is meant to do. Lower case d is the single stage compressor version; d1 and d2 report low and high stage on a communicating two stage system.
Most common causes
- A humidity-controlling thermostat is calling for dehumidification.
- Humid weather, which is when this mode is designed to engage.
- The system configured for a single stage compressor rather than a two stage one.
How to diagnose it
- Note whether the weather is humid and whether the thermostat has a humidity setting. That usually explains it entirely.
- Reduced airflow during this mode is intended, not a fault.
- If the humidity setpoint has been set unrealistically low, the system will run in this mode far more than it should — that is a setting rather than a failure.
- If airflow is low in every mode rather than only this one, then look at filters and ductwork.
How to fix it
- Nothing, if the weather is humid and the thermostat is asking for dehumidification.
- If the system runs this way constantly, check the humidity setpoint on the thermostat before calling anyone.
- Reduced airflow in this mode is by design and should not be countered by raising blower speed.
Notes
This mode is a frequent source of complaints about weak airflow in summer. The furnace is not underperforming; it is trading airflow for moisture removal, deliberately.