Furnace Fault Codes

Heil furnace 1 flash: Not used — if you are counting one flash, count again

ICP lists one flash as not used on this control. Seeing what looks like a single flash almost always means you are watching a heartbeat, or catching the tail of a longer pattern.

Applies to: International Comfort Products *9MPT and *9MPV gas furnaces using the Honeywell SV9541Q SmartValve, sold as Heil, Tempstar and Comfortmaker.

What it means

The SmartValve's code table has no meaning assigned to a single flash. That is genuinely useful information rather than a gap, because it tells you that a one-flash reading is a misread rather than a fault. There are two common ways to get one. A heartbeat pulses continuously and, glimpsed briefly, can look like a single blink. And every longer code ends with a pause before repeating, so joining a pattern partway through and seeing one flash before the pause is easy. Both are solved the same way: watch several full cycles before deciding.

Most common causes

How to diagnose it

  1. Watch at least three complete cycles before counting. A code repeats after a distinct pause; a heartbeat does not.
  2. Look for a combination pattern. This control uses six flashes followed by a further count to indicate the reason for a soft lockout, so a pause mid-pattern is expected.
  3. Confirm which LED you are watching. The SmartValve LED is on the gas valve; the control board has its own with a different meaning for every count.
  4. Check the code legend on the wiring label inside the furnace door, which is authoritative for your specific furnace.

How to fix it

  1. Nothing to fix based on a one-flash reading. Recount first.
  2. If the furnace is not heating and you cannot resolve the pattern, note where the light is and what it does rather than only the count, and give the technician both.
  3. Do not act on a code you are not confident you have read correctly. On this control the adjacent counts include a gas valve fault and a limit circuit fault, which need entirely different responses.

Notes

A manufacturer explicitly documenting a count as unused is worth having. It converts a confusing observation into a definite answer: you have miscounted, and the fault is elsewhere.

Related

All codes for this manufacturer

Heil, Tempstar and Comfortmaker furnace codes — every code, with what differs between models.

Not sure this is your brand?

The same count means something else on other furnaces. What 1 flash means on every brand puts them side by side.

This code is not a homeowner repair. Faults in this group involve the gas valve, the burner compartment, or the heat exchanger — the parts whose failure can put combustion products, including carbon monoxide, into the air the house breathes. Do not reset it repeatedly to keep the heat on. Have it looked at by a licensed technician, and make sure there is a working carbon monoxide alarm on every level of the home, including the level the furnace is on.

Sources

This site is a reference, not a substitute for a licensed HVAC technician. Gas appliances can leak carbon monoxide and cause fire. Anything involving gas lines, the heat exchanger, or the flame sensing circuit should be handled by a licensed professional. Pages are written with AI assistance from the sources listed on each page and checked against them before publishing.