Furnace inducer motor fault codes by brand
The inducer runs first in every heating sequence, so an inducer fault stops the furnace before it ever tries to light. Most inducer codes reach the reader as pressure switch codes.
What the inducer / draft motor does
The inducer is the small blower that pulls combustion air through the burners and heat exchanger and pushes flue gas out of the vent. It starts before ignition, runs through the whole heating cycle, and continues briefly afterwards to purge. Its job is proved indirectly, by the pressure switch it draws against, rather than measured directly.
Why one part produces several different codes
That indirection is why a failing inducer usually shows up as a pressure switch that will not close rather than as an inducer code. A furnace that hums but does not spin, spins slowly, or runs with a bearing noise will produce enough suction to look alive and not enough to close the switch. Codes that name draft or the inducer directly are typically reporting either no inducer feedback at all or a speed the control could not verify.
Every inducer / draft motor code on this site
10 codes across 7 control families. The meaning is the manufacturer's, from the document listed at the foot of each code page.
| Brand | Code | What it reports |
|---|---|---|
| Armstrong | 11 flashes | Pressure switch stuck closed before the inducer started |
| Goodman | EC | Inducer motor overcurrent |
| Goodman | 2 red flashes | Pressure switch stuck closed, or an inducer error |
| Goodman | 3 double red flashes | Second stage pressure switch stuck open, or an inducer error |
| Goodman | 3 red flashes | First stage pressure switch stuck open, or an inducer error |
| Heil | 3 flashes | Low pressure switch still open 30 seconds after the inducer started |
| Lennox | Alert code 228 | Inducer calibration issue |
| Lennox | Alert code 294 | Inducer motor overcurrent — Watchguard |
| Trane | 3 flashes | Draft pressure error |
| York | 2 red flashes | Pressure switch stuck closed, or an inducer error |
Before you work on it
The inducer is the component that keeps flue gas moving out of the house. A furnace that keeps failing to prove draft should not be run repeatedly while the cause is unknown.
Other parts
- Furnace pressure switch codes on every brand
- Furnace high limit switch codes by brand
- Furnace flame sensor codes on every brand
- Furnace rollout switch codes: why it tripped
- Furnace igniter fault codes by manufacturer
- Furnace gas valve fault codes by manufacturer
- Furnace grounding and reversed polarity codes
Sources
Every code meaning above comes from the manufacturer document behind its code page:
- Allied Air Enterprises — A80UH1E and 80G1UHE Installation Instructions 507330-03, Table 7: Diagnostic Codes for -02 Control
- Goodman Manufacturing — Diagnostic Code Identification System (model-specific fault code lookup)
- International Comfort Products *9MPT and *9MPV installation instructions — Gas Valve Diagnostic Codes (third-party archive of the ICP document)
- Lennox Residential Communicating Systems Alert Code Guide, document 100017, March 2023 — Table 2, Alert Codes and Troubleshooting
- Trane Installer's Guide 18-CD29D1-14-EN — Table 21, Integrated Furnace Control Error Flash Codes
- Johnson Controls Unitary Products technical service letter ST-045-09 — York UTEC furnace boards, fault code tables and retrieval procedure