A tripped high limit means the furnace got too hot. Every brand has codes for it, and the cause is almost never the switch itself.
What the high limit switch does
The high limit is a temperature-sensing switch in the heat exchanger compartment that opens when the air leaving the furnace exceeds a set temperature. It is normally closed, wired in series with any other limits, and opening it shuts off the gas valve while leaving the blower running to clear the heat.
Why one part produces several different codes
A limit that opens is reporting a real overheat, and the overheat is nearly always a lack of airflow across the heat exchanger — a clogged filter, closed or blocked registers, an undersized or crushed return duct, a failed or slow blower motor, or a blower wheel packed with dirt. Replacing a limit switch that is doing its job correctly leaves the overheat in place and removes the protection against it.
Every high limit switch code on this site
17 codes across 11 control families. The meaning is the manufacturer's, from the document listed at the foot of each code page.
| Brand | Code | What it reports |
|---|---|---|
| Armstrong | 7 flashes | Primary or secondary limit open, or Watchguard after three minutes open |
| Goodman | 4 flashes | High limit switch is open — the furnace is overheating |
| Goodman | 6 flashes | Rollout limit open, or control module fuse blown |
| Goodman | E3 | High limit switch is open — the furnace is overheating |
| Goodman | 4 red flashes | Open limit switch |
| Goodman | 11 red flashes | Limit switch open due to blower failure |
| Heil | 4 flashes | Limit switch string is open |
| Heil | 7 flashes | Soft lockout — limit trips taking longer than two minutes to reset |
| Lennox | Alert code 200 | Rollout limit switch open |
| Lennox | Alert code 250 | Primary limit switch open |
| Lennox | Alert code 274 | Primary limit switch open more than three minutes — Watchguard |
| Lennox | E250 | Limit switch circuit open |
| Rheem | 3 blinks | Limit switch open |
| Trane | 4 flashes | Open high limit device |
| Trane | E09 | Open inducer limit switch or condensate pressure switch |
| York | 4 red flashes | Open high limit switch |
| York | 11 red flashes | Limit switch open more than five minutes — blower failure |
Before you work on it
Repeated limit trips overheat the heat exchanger, which is the component whose failure lets combustion gases into the supply air. A furnace that keeps tripping on limit needs the airflow problem found, not the limit replaced.
What the fixes cost
The furnace repair cost guide lists a limit switch at $150–350, annotated with this page's own thesis: find why it tripped, not just the part. The realistic bills follow the causes. A meaningful share cost almost nothing — a clogged filter or closed registers found during the $75–150 diagnostic. The middle case is blower-side: a PSC blower's failed capacitor at $150–350, which the blower cost guide says any honest technician tests before condemning a motor, or the motor itself at $400–1,500. The tail risk is why deferral is expensive: repeated limit trips overheat the heat exchanger, and at $1,000–2,500+ the exchanger is usually the replace-the-furnace conversation.
Do it yourself or call someone?
Homeowner work on a limit code is exactly two items: a fresh filter and open supply registers. Both fix real cases, cost pocket change, and need no tools. The discipline is in what follows if the code returns anyway — stop resetting and book the visit, because each further trip is another overheat through the exchanger. Diagnosing weak airflow beyond the filter means blower amp draws and capacitor tests on live line voltage, with capacitors holding charge even after power-off; that half belongs to the technician.
Other parts
- Furnace pressure switch codes on every brand
- Furnace flame sensor codes on every brand
- Furnace rollout switch codes: why it tripped
- Furnace igniter fault codes by manufacturer
- Furnace inducer motor fault codes by brand
- Furnace blower motor fault codes by brand
- Furnace gas valve fault codes by manufacturer
- Furnace grounding and reversed polarity codes
- Furnace voltage and fuse codes by brand
Sources
Every code meaning above comes from the manufacturer document behind its code page:
- Allied Air Enterprises — A80UH1E and 80G1UHE Installation Instructions 507330-03, Table 7: Diagnostic Codes for -02 Control
- Goodman Manufacturing — Diagnostic Code Identification System (model-specific fault code lookup)
- International Comfort Products *9MPT and *9MPV installation instructions — Gas Valve Diagnostic Codes (third-party archive of the ICP document)
- Lennox Residential Communicating Systems Alert Code Guide, document 100017, March 2023 — Table 2, Alert Codes and Troubleshooting
- Lennox ML193UHEK Installation Instructions 508565-01, May 2026 — Integrated Diagnostic Codes / Status of Equipment
- Rheem Professional Technical Support — Standard Gas Furnace Diagnostic Flash Codes
- Trane Installer's Guide 18-CD29D1-14-EN — Table 21, Integrated Furnace Control Error Flash Codes
- Trane Installer's Guide 18-CE01D1-1E-EN — S9V2 two-stage condensing variable speed furnaces, Integrated Furnace Control Display Codes
- Johnson Controls Unitary Products technical service letter ST-045-09 — York UTEC furnace boards, with the previous White-Rodgers Emerson code table reproduced for comparison