Trane and American Standard furnace flash codes
Trane's integrated furnace control reports faults as a flash count, and uses the flash rate itself to signal normal operation — slow for idle, fast for a call for heat.
Also covers: American Standard — same manufacturer, same controls, same codes.
Trane and American Standard are the same manufacturer and use the same integrated furnace control. Unlike most manufacturers, Trane uses the rate of flashing as well as the count: a slow steady flash means idle with no call for heat, and a fast steady flash means the furnace is responding to a call. Neither is a fault. Counted flashes from two to nine are the actual fault codes.
Worth knowing before you count
Fast flashing means normal operation on a Trane control and means a fault on several other manufacturers' boards. If you have owned a different furnace before, that convention does not carry over. A steadily lit LED that never flashes is Trane's instruction to replace the control.
Trane and American Standard
- 2 flashes — System lockout — retries or recycles exceeded
- 3 flashes — Draft pressure error
- 4 flashes — Open high limit device
- 5 flashes — Flame sensed when no flame should be present
- 6 flashes — 115 volt AC power reversed, or poor grounding
- 7 flashes — Gas valve circuit error
- 8 flashes — Low flame sense signal
- 9 flashes — Ignitor circuit problem, or low voltage between neutral and 24 volt common
- Flashing slow — Normal — no call for heat
- Flashing fast — Normal — call for heat
- Continuous on — Replace the integrated furnace control
- Continuous off — Check power
Other manufacturers
- Goodman and Amana furnace fault codes
- Carrier, Bryant and Payne furnace status codes
- Lennox furnace alert codes
- York, Luxaire and Coleman furnace flash codes
- Rheem, Ruud and Weather King furnace blink codes
- Heil, Tempstar and Comfortmaker furnace codes
- Armstrong Air, AirEase, Concord and Ducane furnace codes