Lennox furnace E223: Pressure switch failed open
E223 means the pressure switch did not close when it should have. The inducer is running but the control never got the signal that proves the flue is clear, so it will not light the burners.
Applies to: Lennox gas furnaces with a seven-segment diagnostic display on the control board, such as the ML193UHEK, per installation instructions 508565-01.
What it means
The pressure switch is a diaphragm switch connected by a small hose to the inducer housing. Suction from a running inducer pulls it closed, and that closure is the proof the control needs before it will energise the igniter and open the gas valve. A switch that stays open means either the suction is not there or the switch cannot respond to it. Lennox's troubleshooting is unusually concrete: check the pressure in inches of water column at which the switch closes on a heat call, measure the actual operating pressure, and inspect the vent and combustion air inducer for correct operation and restriction. That turns a parts-swap into a measurement — the switch either sees the pressure it needs or it does not, and the number says which.
Most common causes
- A blocked vent or intake termination outside — snow, ice, a nest, or a cap left in place.
- Water in the pressure switch hose, the collector box, or a blocked condensate drain.
- A cracked, kinked or disconnected hose.
- An inducer running but not developing enough suction, from worn bearings or a dirty wheel.
- A failed pressure switch, or one of the wrong specification fitted previously.
How to diagnose it
- Check the vent and intake terminations outside. This is homeowner work and it resolves a large share of these in cold weather.
- Note whether the inducer sounds normal, weak or noisy.
- Note any standing water near the furnace, which points at the condensate path.
- Everything inside the cabinet is technician work.
How to fix it
- Clear the vent or intake termination if it is blocked.
- Otherwise this is a technician job, and Lennox's own steps are measurements rather than replacements.
- Never jumper the pressure switch to force the furnace to fire. That interlock is what stops it burning gas when the flue is not clear.
Notes
E223 and E224 are the two halves of the same switch. Failed open means it never closed; failed closed means it was already closed before the inducer started, so it could not prove anything.