Furnace voltage and fuse codes by brand
A blown control-board fuse is almost never the fault. It is the evidence of one, and fitting a new fuse without finding what opened the old one simply blows the new one.
What the voltage and fuse does
A furnace runs on two supplies at once. Line voltage, 115 V in most homes, drives the motors, the igniter and the transformer. The transformer steps that down to 24 V for the control circuit — the thermostat, the switches, the gas valve coil — and a small fuse on the control board, usually rated three or five amps, protects that low-voltage side. Codes in this group report either that a supply is outside the range the control will run on, or that the fuse protecting the low-voltage side has opened.
Why one part produces several different codes
Those two are diagnosed in opposite directions. A supply complaint — low line voltage, high line voltage, a frequency outside the accepted band — is usually about what is arriving at the furnace rather than the furnace itself: a brownout, an undersized or shared circuit, a long run of thin cable, or a generator whose output is not a clean 60 Hz. That last one catches people out during an outage, because a furnace that will not run on generator power is often reporting exactly this and is not damaged. A blown low-voltage fuse is the opposite: it is a symptom, and the fault is a short somewhere on the 24 V side. Pinched thermostat cable, a condensate switch wire rubbed through against sheet metal, and a scorched wire near the burner compartment are the usual places. Note also that several manufacturers report a blown fuse and an open rollout switch on the same code, so on those boards the same signal means either — and one of the two is a safety fault.
Every voltage and fuse code on this site
19 codes across 11 control families. The meaning is the manufacturer's, from the document listed at the foot of each code page.
| Brand | Code | What it reports |
|---|---|---|
| Armstrong | 1 flash | Reverse line voltage polarity |
| Armstrong | 13 flashes | Low line voltage |
| Carrier | LED rapid flashing | Line voltage polarity reversed |
| Carrier | Status code 24 | Secondary voltage fuse is open |
| Goodman | 6 flashes | Rollout limit open, or control module fuse blown |
| Goodman | b6 | Blower motor over or under voltage trip, or over temperature trip |
| Goodman | E5 | Low voltage fuse is open |
| Goodman | 5 red flashes | Open rollout switch, or open fuse detected |
| Lennox | Alert code 116 | High 24 volt secondary voltage |
| Lennox | Alert code 370 | Interlock switch open — no 24 volts at the DS terminal |
| Lennox | E110 | Low line voltage |
| Lennox | E111 | Line voltage polarity reversed |
| Lennox | E113 | High line voltage |
| Lennox | E114 | Line voltage frequency out of range |
| Lennox | E115 | Low 24 volt supply |
| Trane | 9 flashes | Ignitor circuit problem, or low voltage between neutral and 24 volt common |
| Trane | E6.1 | Line voltage polarity reversed |
| Trane | E12 | Open fuse |
| York | Rapid red flashing | Twinning error or incorrect 24 volt phasing |
Before you work on it
Never fit a fuse of a higher rating than the one that opened. The fuse is sized to the wiring it protects, and a larger one lets a shorted low-voltage circuit keep drawing current through cable that cannot carry it. If a correctly rated fuse opens again, the short is still there and needs finding rather than working around.
Other parts
- Furnace pressure switch codes on every brand
- Furnace high limit switch codes by brand
- Furnace flame sensor codes on every brand
- Furnace rollout switch codes: why it tripped
- Furnace igniter fault codes by manufacturer
- Furnace inducer motor fault codes by brand
- Furnace blower motor fault codes by brand
- Furnace gas valve fault codes by manufacturer
- Furnace grounding and reversed polarity codes
Sources
Every code meaning above comes from the manufacturer document behind its code page:
- Allied Air Enterprises — A80UH1E and 80G1UHE Installation Instructions 507330-03, Table 7: Diagnostic Codes for -02 Control
- Carrier 58MCB Service Manual, 327884-101 Rev. B — status codes
- Goodman Manufacturing — Diagnostic Code Identification System (model-specific fault code lookup)
- Lennox Residential Communicating Systems Alert Code Guide, document 100017, March 2023 — Table 2, Alert Codes and Troubleshooting
- Lennox ML193UHEK Installation Instructions 508565-01, May 2026 — Integrated Diagnostic Codes / Status of Equipment
- Trane Installer's Guide 18-CD29D1-14-EN — Table 21, Integrated Furnace Control Error Flash Codes
- Trane Installer's Guide 18-CE01D1-1E-EN — S9V2 two-stage condensing variable speed furnaces, Integrated Furnace Control Display Codes
- Johnson Controls Unitary Products technical service letter ST-045-09 — York UTEC furnace boards, fault code tables and retrieval procedure