Goodman GMV8 furnace fault codes

Every diagnostic code Goodman publishes for the GMV8 series — 12 of them — taken from the manufacturer's own per-model fault code database rather than from a general table.

Codes differ between models from the same manufacturer, which is why this list is worth reading in preference to a brand-wide one. Six flashes means a rollout switch on some Goodman models and a rollout limit or a blown control module fuse on others. A count that appears on one board may not exist on another at all.

GMV8 codes

What the LED showsWhat it means
LED offNo power to the furnace, or an internal control fault
continuous onNormal operation — no fault stored
rapid flashingReversed 115 volt polarity, a grounding problem, or an open igniter circuit
1 flashLockout after too many failed ignition attempts
2 flashesPressure switch is closed when it should be open
3 flashesPressure switch will not close
4 flashesHigh limit switch is open — the furnace is overheating
5 flashesFlame detected when no flame should be present
6 flashesRollout switch has tripped
7 flashesFlame signal is too weak
8 flashesIgniter circuit fault, most often caused by poor grounding
9 flashesHigh stage pressure switch stuck open

Other Goodman models

Amana models

This site is a reference, not a substitute for a licensed HVAC technician. Gas appliances can leak carbon monoxide and cause fire. Anything involving gas lines, the heat exchanger, or the flame sensing circuit should be handled by a licensed professional. Pages are written with AI assistance from the sources listed on each page and checked against them before publishing.