Furnace Fault Codes

Amana AMEC96 furnace fault codes

Every diagnostic code Amana publishes for the AMEC96 series — 24 of them — taken from the manufacturer's own per-model fault code database rather than from a general table.

Codes differ between models from the same manufacturer, which is why this list is worth reading in preference to a brand-wide one. Six flashes means a rollout switch on some Goodman models and a rollout limit or a blown control module fuse on others. A count that appears on one board may not exist on another at all.

AMEC96 codes

What the LED showsWhat it means
rapid amber flashingLow flame sense current
rapid green flashingNormal operation — fan only, no heating or cooling
rapid red flashingTwinning error
solid redInternal control fault, gas valve error, microprocessor or frequency check failure
solid greenStandby — powered, no call
1 amber flashNormal operation — first stage heat
1 red flashFlame sensed when no flame should be present
1 green flashNormal operation — low stage cooling
10 red flashesGas flow detected with a call for heat
11 red flashesLimit switch open due to blower failure
12 red flashesIgnitor relay failure
2 amber flashesNormal operation — second stage heat
2 red flashesPressure switch stuck closed, or an inducer error
2 green flashesNormal operation — high stage or single stage cooling
3 amber flashesSecond stage heat called with no first stage call
3 red flashesFirst stage pressure switch stuck open, or an inducer error
3 double red flashesSecond stage pressure switch stuck open, or an inducer error
4 amber flashesCooling called with no fan call
4 red flashesOpen limit switch
5 red flashesOpen rollout switch, or open fuse detected
6 red flashesPressure switch cycle lockout
7 red flashesExternal lockout — ignition retries exhausted
8 red flashesExternal lockout — recycles exhausted
9 red flashesGrounding problem or reversed polarity

Other Amana models

Goodman models

This site is a reference, not a substitute for a licensed HVAC technician. Gas appliances can leak carbon monoxide and cause fire. Anything involving gas lines, the heat exchanger, or the flame sensing circuit should be handled by a licensed professional. Pages are written with AI assistance from the sources listed on each page and checked against them before publishing.