Every diagnostic code Amana publishes for the AMSS9 series — 11 of them — taken from the manufacturer's own per-model fault code database rather than from a general table.

Codes differ between models from the same manufacturer, which is why this list is worth reading in preference to a brand-wide one. Six flashes means a rollout switch on some Goodman models and a rollout limit or a blown control module fuse on others. A count that appears on one board may not exist on another at all.

AMSS9 codes

What the LED showsWhat it means
continuous onNormal operation — no fault stored
LED offNo power to the furnace, or an internal control fault
rapid flashingReversed 115 volt polarity, a grounding problem, or an open igniter circuit
1 flashLockout after too many failed ignition attempts
2 flashesPressure switch is closed when it should be open
3 flashesPressure switch will not close
4 flashesHigh limit switch is open — the furnace is overheating
5 flashesFlame detected when no flame should be present
6 flashesRollout limit open, or control module fuse blown
7 flashesFlame signal is too weak
8 flashesIgniter circuit fault, most often caused by poor grounding

Other Amana models

Goodman models

This site is a reference, not a substitute for a licensed HVAC technician. Gas appliances can leak carbon monoxide and cause fire. Anything involving gas lines, the heat exchanger, or the flame sensing circuit should be handled by a licensed professional. Pages are written with AI assistance from the sources listed on each page and checked against them before publishing.